Skip To Content

Configuring event replacement

Mit der Location Referencing-Lizenz verfügbar.

While performing pipeline maintenance, sometimes a section of a pipe is taken out of the ground and is replaced by a new pipe. This process is known as pipe replacement.

During the pipe replacement, the events that were part of the replaced pipe can be left as is, retired, or retired and replaced using the Event Replacement widget. The measures for the route do not change.

Event replacement scenario

The configuration of event replacement requires categorizing the events in the map service into three categories: As Is, Retire, and Retire and Replace using the Configure Event Replacement widget.

Before event replacement

The following diagram illustrates a pipeline section before replacement.

Pipe before replacement
Pipeline events before replacement are shown.

Before replacement, the pipe section has eight events, three point events (events 1-3) and five linear events (events 4-8).

Table 1: Event table before replacement

Event layerEvent IDFrom measureTo measureValueFrom dateTo date

Event 1

1A

1

GGG

1/1/2000

Null

Event 2

2A

2

SSS

1/1/2000

Null

Event 3

3A

3

HHH

1/1/2000

Null

Event 4

4A

0

10

XXX

1/1/2000

Null

Event 5

5A

0

10

YYY

1/1/2000

Null

Event 6

6A

0

10

ZZZ

1/1/2000

Null

Event 7

7A

0

10

QQQ

1/1/2000

Null

Event 8

8A

0

10

WWW

1/1/2000

Null

A pipe with measures from 0 to 10 exists. Various line and point events are present in the pipe as shown above.

During inspection, it was determined that a section of the pipe between the measures 0 and 5 needs to be replaced on 12/31/2017, as shown below.

Section of the pipe to be replaced
The section of the pipe to be replaced and affected events are shown.

The events are placed in the following event replacement categories:

Table 2: Event replacement categories

RetireRetire and replaceKeep as is

Event 2

Event 5

Event 1

Event 3

Event 8

Event 7

Event 4

Event 6

After event replacement

The results of replacing the pipe and events are shown in the following diagram and in Table 3.

Event replacement in pipeline
Event replacement on a new pipe section is shown.

Table 3: After event replacement

Event layerEvent IDFrom measureTo measureValueFrom dateTo dateCase

Event 1

1A

1

GGG

1/1/2000

Null

A

Event 2

2A

2

SSS

1/1/2000

12/31/2017

B

Event 3

3A

3

HHH

1/1/2000

12/31/2017

C

Event 4

4A

0

10

XXX

1/1/2000

12/31/2017

D

Event 4

4B

5

10

XXX

12/31/2017

Null

E

Event 5

5A

0

10

YYY

1/1/2000

12/31/2017

F

Event 5

5B

5

10

YYY

12/31/2017

Null

G

Event 5

5C

0

5

YYYOO

12/31/2017

Null

H

Event 6

6A

0

10

ZZZ

1/1/2000

12/31/2017

I

Event 6

6B

5

10

ZZZ

12/31/2017

Null

J

Event 7

7A

0

10

QQQ

1/1/2000

Null

K

Event 8

8A

0

10

WWW

1/1/2000

12/31/2017

L

Event 8

8B

5

10

WWW

12/31/2017

Null

M

Event 8

8C

0

5

WWWOO

12/31/2017

Null

N

Table 4: Explanation of event replacement

CaseEvent layerExplanation

A

Event 1

The event is left as is.

B

Event 2

The event is retired because it was in the retire category.

C

Event 3

The event is retired because it was in the retire category.

D

Event 4

The whole event is retired because it was in the retire category.

E

Event 4

A new event is created for the existing section of the pipe, keeping the attribute values of the old event.

F

Event 5

The whole event is retired because it was in the retire and replace category.

G

Event 5

A new event is created for the existing section of the pipe, keeping the attribute values of the old event.

H

Event 5

A new event is created for the new section of the pipe with the new dates and attributes provided in the Event Replacement widget.

I

Event 6

The whole event is retired because it was in the retire category.

J

Event 6

A new event is created for the existing section of the pipe, keeping the attribute values of the old event.

K

Event 7

The event is left as is.

L

Event 8

The whole event is retired because it was in the retire and replace category.

M

Event 8

A new event is created for the existing section of the pipe, keeping the attribute values of the old event.

N

Event 8

A new event gets created for the new section of the pipe with the new dates and attributes provided in the Event Replacement widget.

Categorizing events

The configuration of event replacement requires categorizing the events in the map service into three categories: As Is, Retire, and Retire and Replace.

To configure event replacement, complete the following steps:

  1. Öffnen Sie Event Editor, und melden Sie sich bei Ihrer ArcGIS-Organisation an, wenn Sie dazu aufgefordert werden.
  2. Click the Edit tab.
  3. In the Edit Events group, click the Configure Event Replacement button Objektersetzung konfigurieren.

    The Configure Event Replacement widget appears.

    Tipp:

    All the line events Line Events and point events Point Events available in the map service are listed in the Available Event Layers list.

    Opening the Configure Event Replacement widget

    Opening the Configure Event Replacement widget

    Tipp:

    If a default configuration has been created, click Default to load it. Click Reset to return to the last saved configuration in the map service.

  4. Click Shift or Ctrl and click and drag multiple line events from the Available Event Layers list to the Retire Events list.
    Choosing events for retirement
    Choosing events for retirement

    You can also choose event categories and use the arrow keys to move chosen line events into the lists from left to right or up and down between the Retire Events and Retire and Replace Events lists.

    Events placed in the Retire Events list are retired when events in the category are replaced using the Event Replacement widget.

    Choosing events for retirement and replacement
    Choosing events for retirement and replacement
  5. Click Shift or Ctrl and click and drag multiple line events from the Available Event Layers list to the Retire and Replace Events list.
    Tipp:

    Only line events Line Events can be retired and replaced.

    Event replacement configured
    Event replacement configured
    Hinweis:

    Event layers left in the Available Event Layers list are left as is. If no events are configured to retire or to retire and replace, you'll be unable to save using the Event Replacement widget.

  6. Optionally, click the arrow for any event layer in the Retire and Replace Events list to expand it.

    An expanded list of fields in the event layer appears.

    Expanded event layer fields
    Expanded event layer fields

    You can use these check boxes to show or hide the fields when performing the event replacement operation.

    Hinweis:

    Some attribute fields are required fields, which is denoted by the asterisk (*) symbol. A required field is a nonnullable field with no default value. Visibility can't be changed for required fields.

  7. Click Save to save the event replacement configuration.
  8. Click Export to export the configuration to an LRER file. Give the configuration file a name such as eventplacement1.lrer.
    Hinweis:

    The event replacement configuration is saved in the local browser’s download folder.

  9. Copy the exported file to the Event Editor folder.
  10. Open the configuration file (config.json) in a text editor such as Microsoft Notepad.
  11. Type the LRER file name with the file extension in the eventReplacement section:
    The eventReplacement section of
    Hinweis:

    The Default button defaults to the event replacement configuration provided in the Event Editor configuration file.

    The Reset button restores the last saved event replacement configuration for that browser.

    You can edit the default event replacement configuration and use it in your browser.

Verwandte Themen